Indramat HVE DIAX 04 power supplies
Air-cooled supply units that create the shared DC bus for DIAX 04 drive systems.

HVE inventory and offers
Inventory records include a Finale catalog export dated 2026-10-23. Choose the complete item below to inquire or make an offer. Call to verify current stock, condition and quantity.
Showing 4 of 4 matching listings
HVE03.1-W030N
Inventory record — verify current availabilitySource records: 2026-08-22 · 2026-09-16HVE03.2-W030N
Inventory record — verify current availabilitySource records: 2026-08-22 · 2026-09-16HVE04.2-W075N
Inventory record — verify current availabilitySource records: 2026-08-22 · 2026-09-16From Litco’s inventory photo collection
HVE product photos
Browse the complete codes beneath each photo. These are photographed examples; call for the current unit, condition and availability.
HVE02.2-W018N
Terminal cover is absent in this reference photo; not a ready-to-ship representation. Photo matched to this complete designation in Finale inventory.
View product details →Call 210-680-9570HVE04.2-W075N
Photo matched to this complete designation in Finale inventory.
View product details →Call 210-680-9570Scrollable family inventory
HVE types Litco can check
The list below is a starting point, not the warehouse limit. Call with the full suffix from the tag for current condition, configuration and price.
HVE04.2-W075N
Indramat HVE04.2 second-generation supply with an unregulated DC bus; available power depends on mains and choke configuration.
View HVE04.2-W075N exact-part page →HVE02.2-W018N
A second-generation HVE power-supply module for Bosch Rexroth Indramat DIAX 04 systems.
View HVE02.2-W018N exact-part page →Family overview
About HVE
HVE supplies convert three-phase mains power for connected DIAX controllers and manage braking energy through the family’s standard arrangement. Match power code, mains range and cabinet load.
What to check before replacement or repair
Power modules are selected as part of a cabinet, not as isolated boxes. The incoming power, connected axes and braking cycle all affect the correct replacement.
- Complete supply type code and power designation
- Mains voltage, transformer and line components
- Connected drive modules and total cabinet load
- Braking, bleeder, regeneration, fan and cooling arrangement
Record the cabinet fault, line conditions and connected load before removing the supply. Photos of adjacent modules and wiring give Litco the system context needed for evaluation.
Helpful photos: the nameplate, complete unit, connections and shaft or cabinet context.
Call to check stock. Send the complete HVE type code so Litco can confirm configuration, condition and availability.
Get a replacement or repair quote.
Your part number carries into the form. Tell us what you need and how soon you need it.