Industrial motion control since 1988 · Search part numbers210-680-9570 · Se Habla Español · Shop Litco on eBay ↗
BrandIndramatBosch Rexroth · Indramat
Product identificationHVE02.2-W018N

Match the complete nameplate, including every suffix. Ask Litco for current photos of the unit being quoted.

Power Supplies · HVE family

HVE02.2-W018N

DIAX 04 HVE power supply unit

A second-generation HVE power-supply module for Bosch Rexroth Indramat DIAX 04 systems.

Call to check stock and condition

Ask about repairing this exact unit →

Product description

What to know about HVE02.2-W018N

The HVE02.2-W018N is a Bosch Rexroth Indramat HVE power supply unit for DIAX 04 drive systems. It converts three-phase mains power into the DC bus used by connected drive controllers and provides system-level supply and monitoring functions.

Manufacturer project-planning documentation lists the HVE02.2-W018N as the 18 kW HVE02.2 configuration. The W code denotes cabinet air cooling with an internal blower, while N identifies the standard internal braking-resistor arrangement used in this family.

A supply-module replacement should be checked against mains voltage, connected load, braking requirements and the complete type plate. Litco can quote the unit, repair path or related DIAX components after that configuration check.

Part-number and material references

Identification references

Formatting variants and material references

HVE 02.2-W018NHVE022W018N
Can’t find your exact suffix?

Litco’s inventory is not limited to the pages online.

Send the complete nameplate. Litco can check availability or discuss repair.

Call Litco now about this part →
Compatibility checklist

Before replacing HVE02.2-W018N, match the complete nameplate and machine configuration.

  • Complete supply code: Verify the family, design, power rating, voltage class, cooling field, material number and all suffixes on the nameplate.
  • Cabinet configuration: Identify incoming mains, transformer and line components, connected drive modules, total axis load and DC-bus arrangement.
  • Braking and cooling: Record bleeder, regeneration, braking resistor, fan or cooling hardware and the machine duty that loads the supply.
  • Fault evidence: Include fault indicators, fuse or breaker history, operating state and clear connection photos before the module is removed.

For repair, send the fault or symptoms. Helpful photos show the tag, complete unit, mounting and connections.

Get a replacement or repair quote.

Call to check stock, condition and lead time. Your part number carries into the form.

Quick QuoteCall 210-680-9570Add photos or repair details →