Indramat TVR3.1 regenerative power supplies
TVR3.1-W015-03 is the documented standard configuration, supplying a regulated 320 V DC bus from three-phase 380–480 VAC mains.

Models
Known TVR3.1 catalog pages
Send the complete nameplate code so Litco can check availability, condition and compatibility.
Call 210-680-9570From Litco’s inventory photo collection
TVR3.1 product photos
Browse the complete codes beneath each photo. These are photographed examples; call for the current unit, condition and availability.
Series overview
What TVR3.1 identifies
The Indramat application manual documents TVR3.1 as a regulated power supply for a modular AC drive system. It supplies DC-bus and control voltages to connected main and servo drive modules and returns motor braking energy to the mains. Direct-mains use, transformer use, grounding, commutation choke, connected load and accessory selection remain system-engineering decisions.
Ratings, connections, feedback, braking and mechanical options vary by complete type code. Send Litco Automation a clear nameplate photo so the exact configuration and compatible replacement can be confirmed.
Technical specifications
Documented TVR3.1 order-code fields
These values come from the preserved type-code reference. They describe documented ordering fields, not a promise that every theoretical combination was produced or is currently in stock.
- Documented standard configuration
- TVR3.1-W015-03
- Type-code fields
- TVR direct-mains regenerative supply · series 3 · version 1 · W cooling-code position · 015 nominal-power position · 03 DC-bus code
- Mains input
- 3 × 380–480 VAC ±10% · 50–60 Hz
- Regulated DC bus
- 320 VDC ±5%
- Continuous DC-bus power
- 15 kW feed side · 10 kW regeneration side
- Continuous mechanical load
- Up to 12 kW in the documented application range
- Short-time / peak DC-bus power
- 3 s: 30 kW feed and 20 kW regeneration · 0.3 s: 45 kW feed and 25 kW regeneration
- Peak bleeder power
- 40 kW; manufacturer data describes the bleeder as emergency-stop only
- Environment / protection
- +5 to +45°C rated · derated to +55°C · IP10 · 31 kg
- Connected modules
- The manual documents up to ten drive modules on one TVR3.1 supply when the system is engineered accordingly
- Associated components listed
- GLD 17 smoothing choke · KD 23 commutation choke · NAM 1.2-15 or optional TBM 1.2 auxiliary bleeder arrangement
- Connection qualification
- Direct mains is documented for suitable systems, but commutation, grounding and transformer requirements depend on the installation
Configuration checklist
Identification guide
Match the whole TVR3.1 configuration
- Complete TVR series, version and power code
- Three-phase mains voltage and grounding arrangement
- Connected drive modules and continuous mechanical load
- Commutation and smoothing chokes plus optional bleeder hardware
- DC-bus, control-voltage and cabinet conditions
- Regenerative modular AC drive systems
- Legacy main and servo drive cabinets
- Machine-tool drive systems
- Multi-axis production machinery
Series questions
TVR3.1 questions
Before Litco pulls a unit
Is TVR3.1 enough information to order a replacement?+
No. TVR3.1 identifies the series group, but the complete type code still carries the power, mains, braking, cooling, DC-bus and cabinet options that determine compatibility.
Which TVR3.1 fields should I compare first?+
Start with complete tvr series, version and power code; three-phase mains voltage and grounding arrangement; connected drive modules and continuous mechanical load. Then preserve the remaining suffix, material number, revision and every installed option or firmware label.
Where is TVR3.1 equipment commonly used?+
TVR3.1 is documented for regenerative modular ac drive systems, legacy main and servo drive cabinets, machine-tool drive systems, multi-axis production machinery. The installed machine, axis and connected equipment still control the final replacement decision.
Can Litco evaluate a failed TVR3.1 unit?+
Yes. Litco can discuss replacement, repair and exchange paths after reviewing the complete code, application and failure information.
Get a replacement or repair quote.
Your part number carries into the form. Tell us what you need and how soon you need it.