- Complete TVR series, version and power code
- Three-phase mains voltage and grounding arrangement
- Connected drive modules and continuous mechanical load
- Commutation and smoothing chokes plus optional bleeder hardware
- DC-bus, control-voltage and cabinet conditions
Indramat TVR3.1 regenerative power supplies
TVR3.1-W015-03 is the documented standard configuration, supplying a regulated 320 V DC bus from three-phase 380–480 VAC mains.
Match the complete nameplate, including every suffix. Ask Litco for current photos of the unit being quoted.
Models
Known TVR3.1 catalog pages
Send the complete nameplate code so Litco can check availability, condition and compatibility.
Call 210-680-9570Series overview
What TVR3.1 identifies
The Indramat application manual documents TVR3.1 as a regulated power supply for a modular AC drive system. It supplies DC-bus and control voltages to connected main and servo drive modules and returns motor braking energy to the mains. Direct-mains use, transformer use, grounding, commutation choke, connected load and accessory selection remain system-engineering decisions.
Ratings, connections, feedback, braking and mechanical options vary by complete type code. Send Litco Automation a clear nameplate photo so the exact configuration and compatible replacement can be confirmed.
Technical specifications
Documented TVR3.1 order-code fields
These values come from the preserved type-code reference. They describe documented ordering fields, not a promise that every theoretical combination was produced or is currently in stock.
- Documented standard configuration
- TVR3.1-W015-03
- Type-code fields
- TVR direct-mains regenerative supply · series 3 · version 1 · W cooling-code position · 015 nominal-power position · 03 DC-bus code
- Mains input
- 3 × 380–480 VAC ±10% · 50–60 Hz
- Regulated DC bus
- 320 VDC ±5%
- Continuous DC-bus power
- 15 kW feed side · 10 kW regeneration side
- Continuous mechanical load
- Up to 12 kW in the documented application range
- Short-time / peak DC-bus power
- 3 s: 30 kW feed and 20 kW regeneration · 0.3 s: 45 kW feed and 25 kW regeneration
- Peak bleeder power
- 40 kW; manufacturer data describes the bleeder as emergency-stop only
- Environment / protection
- +5 to +45°C rated · derated to +55°C · IP10 · 31 kg
- Connected modules
- The manual documents up to ten drive modules on one TVR3.1 supply when the system is engineered accordingly
- Associated components listed
- GLD 17 smoothing choke · KD 23 commutation choke · NAM 1.2-15 or optional TBM 1.2 auxiliary bleeder arrangement
- Connection qualification
- Direct mains is documented for suitable systems, but commutation, grounding and transformer requirements depend on the installation
Configuration checklist
Identification guide
Match the whole TVR3.1 configuration
- Regenerative modular AC drive systems
- Legacy main and servo drive cabinets
- Machine-tool drive systems
- Multi-axis production machinery
Series questions
TVR3.1 questions
Before Litco pulls a unit
Is TVR3.1 enough information to order a replacement?+
No. TVR3.1 identifies the series group, but the complete type code still carries the power, mains, braking, cooling, DC-bus and cabinet options that determine compatibility.
Which TVR3.1 fields should I compare first?+
Start with complete tvr series, version and power code; three-phase mains voltage and grounding arrangement; connected drive modules and continuous mechanical load. Then preserve the remaining suffix, material number, revision and every installed option or firmware label.
Where is TVR3.1 equipment commonly used?+
TVR3.1 is documented for regenerative modular ac drive systems, legacy main and servo drive cabinets, machine-tool drive systems, multi-axis production machinery. The installed machine, axis and connected equipment still control the final replacement decision.
Can Litco evaluate a failed TVR3.1 unit?+
Yes. Litco can discuss replacement, repair and exchange paths after reviewing the complete code, application and failure information.
Get a replacement or repair quote.
Call to check stock, condition and lead time. Your part number carries into the form.