Industrial motion control since 1988 · Search part numbers210-680-9570 · Se Habla Español · Shop Litco on eBay ↗
BrandIndramatBosch Rexroth · Indramat
Product identificationHNL02.1R-0980-N0023-A-480-NNNN

Match the complete nameplate, including every suffix. Ask Litco for current photos of the unit being quoted.

Power Supplies · HNL family

HNL02.1R-0980-N0023-A-480-NNNN

IndraDrive mains choke

A 23 A, 480 V-class mains choke for Bosch Rexroth IndraDrive supply units and converters.

Call to check stock and condition

Ask about repairing this exact unit →

Product description

What to know about HNL02.1R-0980-N0023-A-480-NNNN

The HNL02.1R-0980-N0023-A-480-NNNN is a Bosch Rexroth IndraDrive mains choke. Installed ahead of compatible converters or supply units, it helps limit line-current harmonics and isolate the drive system from the mains.

Manufacturer project-planning data lists 3 × 0.98 mH inductance, 23 A nominal current, 3-phase 380–480 VAC at 50/60 Hz and IP20 protection. The published material number is R911321314.

Line chokes are selected as part of the complete power system. Verify the supply-unit type, mains voltage and cabinet wiring before replacement.

Part-number and material references

Identification references

Formatting variants and material references

HNL 02.1R-0980-N0023-A-480-NNNNHNL021R0980N0023A480NNNNR911321314
Can’t find your exact suffix?

Litco’s inventory is not limited to the pages online.

Send the complete nameplate. Litco can check availability or discuss repair.

Call Litco now about this part →
Compatibility checklist

Before replacing HNL02.1R-0980-N0023-A-480-NNNN, match the complete nameplate and machine configuration.

  • Complete supply code: Verify the family, design, power rating, voltage class, cooling field, material number and all suffixes on the nameplate.
  • Cabinet configuration: Identify incoming mains, transformer and line components, connected drive modules, total axis load and DC-bus arrangement.
  • Braking and cooling: Record bleeder, regeneration, braking resistor, fan or cooling hardware and the machine duty that loads the supply.
  • Fault evidence: Include fault indicators, fuse or breaker history, operating state and clear connection photos before the module is removed.

For repair, send the fault or symptoms. Helpful photos show the tag, complete unit, mounting and connections.

Get a replacement or repair quote.

Call to check stock, condition and lead time. Your part number carries into the form.

Quick QuoteCall 210-680-9570Add photos or repair details →