Industrial motion control since 1988 · Search part numbers210-680-9570 · Se Habla Español · Shop Litco on eBay ↗
BrandIndramatBosch Rexroth · Indramat
2AD101 Series · D-length model

2AD101D Indramat spindle motor

2AD101D is the D-length 2AD101 package, documented with BD or BS winding choices and the same forced-air, feedback, mounting, brake and shaft-field structure as the frame family. The D length carries a specific vibration-grade restriction.

Use the documented 2AD101 ordering choices below, then confirm ratings and dimensions against your complete motor code.

Call to check stockSend the complete type code so Litco can check the exact configuration and condition
Product identification2AD101D

Match the complete nameplate, including every suffix. Ask Litco for current photos of the unit being quoted.

2AD101D overview

2AD101D is the D-length variant within the 2AD101 spindle-motor frame. Its documented winding choices are BD winding / BS winding. Use the complete nameplate for compatibility checks.

Source-backed order-code data

2AD101D documented choices

The fields below describe choices published for the D-length model. They are not a generated part number and do not prove that all cross-combinations exist. Preserve punctuation, special suffixes and every restriction from the tag and source chart.

Source: preserved 2AD101 type-code reference. The physical unit, complete factory code and applicable drawings remain authoritative.

Model
2AD101D
Motor platform
Asynchronous three-phase spindle motor
Frame series
2AD101
Motor length
D
Documented winding choices
BD winding · BS winding
Mounting and connection
B05 flange mounting · Top power-terminal position O
Cooling and blower
Codes 1 or 2 · axial blower · AC 230 V · Code 5 · axial blower · AC 115 V
Feedback and encoder
Code 3 · high-resolution motor feedback
Holding brake
Code 0 · without holding brake · Code 1 · electrically engaged holding brake · Code 2 · electrically released holding brake
Shaft, bearing and vibration
A, B or E shaft code · without shaft seal · C, D or H shaft code · with shaft seal · Plain and keyed shaft choices · N · standard bearing · R or S vibration grade
Dimensions, winding and cooling

Mechanical, winding and cooling

Match the installed spindle-motor configuration

03

Mounting & connection

B05 flange mounting

Top power-terminal position O

04

Winding choice

BD winding · BS winding

The winding belongs to this motor length. Do not carry a winding from another 2AD length into a replacement search.

05

Cooling arrangement

Codes 1 or 2 · axial blower · AC 230 V

Code 5 · axial blower · AC 115 V

Feedback, shaft and brake choices

Feedback, brake and shaft choices

Keep the electrical and mechanical interfaces together

Feedback

Match the encoder and connected drive

  • Code 3 · high-resolution motor feedback

Photograph the feedback label, connector and cable path before removal.

Holding brake

Preserve the documented holding function

  • Code 0 · without holding brake
  • Code 1 · electrically engaged holding brake
  • Code 2 · electrically released holding brake

Brake choice and release behavior are part of the complete configuration.

Shaft, bearing & vibration

Verify the physical spindle interface

  • A, B or E shaft code · without shaft seal
  • C, D or H shaft code · with shaft seal
  • Plain and keyed shaft choices
  • N · standard bearing
  • R or S vibration grade

Confirm the installed shaft, seal and bearing arrangement from the unit and code.

Full type-code guide

Full type-code field guide

Read 2AD101D from family to special design

This field guide preserves the meaning of the model and its documented option groups. It does not manufacture a valid suffix or override the source restrictions.

01

2AD

Bosch Rexroth Indramat asynchronous main-spindle motor family

02

101

2AD101 frame group

03

D

D-length motor package

04

Mounting / connection

B05 flange mounting · Top power-terminal position O

05

Cooling

Codes 1 or 2 · axial blower · AC 230 V · Code 5 · axial blower · AC 115 V

06

Winding

BD winding · BS winding

07

Holding brake

Code 0 · without holding brake · Code 1 · electrically engaged holding brake · Code 2 · electrically released holding brake

08

Motor feedback

Code 3 · high-resolution motor feedback

09

Shaft / bearing / vibration

A, B or E shaft code · without shaft seal · C, D or H shaft code · with shaft seal · Plain and keyed shaft choices · N · standard bearing · R or S vibration grade

10

Restrictions / special design

S1 vibration grade is not documented for the D length. The type-code reference documents ordering choices, not proof that every possible field combination was manufactured or is interchangeable.

Get a replacement or repair quote.

Call to check stock, condition and lead time. Your part number carries into the form.

Quick QuoteCall 210-680-9570Add photos or repair details →

Keep browsing

Other 2AD101 motor lengths

C-length · BD winding2AD101CCall to check stockD-length · BD winding / BS winding2AD101DCall to check stock
← Return to the 2AD101 series page
Model questions

2AD101D questions

Before Litco checks a spindle motor

Is 2AD101D a complete replacement part number?+

No. 2AD101D identifies the D-length package in the 2AD101 frame. The complete type code still determines winding, cooling, feedback, mounting, brake, shaft, bearing and special-design choices.

Does Litco have 2AD101D in stock?+

Call to check stock. Litco will search the current shelf using the complete nameplate code and confirm quantity, condition, photographs, price and lead time before quoting.

Can every 2AD101D option on this page be combined?+

No. The page preserves documented ordering choices and known restrictions; it does not claim that every possible combination was manufactured. The complete factory tag and source reference control.

Can Litco evaluate a failed 2AD101D?+

Yes. Send the full code, machine and spindle-drive context, fault symptoms and four useful photographs for a repair, replacement or exchange discussion.

Model-level type-code referencepreserved 2AD101 type-code reference

Documented choices do not prove present inventory or that every option can be combined. Confirm the complete code, source restrictions and physical unit before replacement.

Open Original Type-Code Reference ↗