Industrial motion control since 1988 · Search part numbers210-680-9570 · Se Habla Español
Menu
IndraDrive · MPx-16 to MPx-19 and PSB

IndraDrive MPx-16 to MPx-19 / PSB fault codes & diagnostics

IndraDrive MPx-16 to MPx-19 / PSB diagnostic index: source-listed messages and printed manual references. Match this firmware to your equipment before using a code.

Check the source and revision

DOK-INDRV*-GEN1-DIAG**-RE07-EN-P

18-page diagnostic index excerpt · MPx-16 to MPx-19 and PSB

These are the manufacturer’s index descriptions, not complete causes or repair instructions. “Source PDF page” opens the supplied index; “printed manual reference” identifies the destination in the full manual, which may not be included here.

Find a display message

Keep every letter, number and indicator. These entries describe the source document, not the condition of a particular machine.

Showing 481–560 of 751 source entries

C0111

Command / diagnostic

ID9 + Record length - 1 > length MDT (S-0-0010)

Source PDF · page 12Printed manual reference: 285

C0113

Command / diagnostic

Relation TNcyc (S-0-0001) to TScyc (S-0-0002) error

Source PDF · page 12Printed manual reference: 286

C0116

Command / diagnostic

T3 (S-0-0008) within MDT (S-0-0089 + S-0-0010)

Source PDF · page 12Printed manual reference: 288

C0118

Command / diagnostic

Order of cyclic command value configuration incorrect

Source PDF · page 12Printed manual reference: 288

C0139

Command / diagnostic

T2 (S-0-0089)+length MDT (S-0-0010)>TScyc (S-0-0002)

Source PDF · page 12Printed manual reference: 289

C0151

Command / diagnostic

IDN for command value data container not allowed

Source PDF · page 12Printed manual reference: 289

C0152

Command / diagnostic

IDN for actual value data container not allowed

Source PDF · page 12Printed manual reference: 290

C0175

Command / diagnostic

Producer cycle time of a connection not correct

Source PDF · page 13Printed manual reference: 292

C0227

Command / diagnostic

Error when initializing position of measuring encoder

Source PDF · page 13Printed manual reference: 300

C0228

Command / diagnostic

Initialization velocity measuring encoder too high

Source PDF · page 13Printed manual reference: 301

C0229

Command / diagnostic

Field bus: IDN for cycl. command val. not configurable

Source PDF · page 13Printed manual reference: 301

C0230

Command / diagnostic

Field bus: Max. length for cycl. command val. exceeded

Source PDF · page 13Printed manual reference: 302

C0231

Command / diagnostic

Field bus: IDN for cycl. actual val. not configurable

Source PDF · page 13Printed manual reference: 302

C0232

Command / diagnostic

Field bus: Length for cycl. actual values exceeded

Source PDF · page 13Printed manual reference: 302

C0234

Command / diagnostic

Field bus: P-0-4077 missing for cycl. command values

Source PDF · page 13Printed manual reference: 303

C0238

Command / diagnostic

Order of cyclic command value configuration incorrect

Source PDF · page 13Printed manual reference: 303

C0239

Command / diagnostic

IDN for command value data container not allowed

Source PDF · page 13Printed manual reference: 304

C0240

Command / diagnostic

IDN for actual value data container not allowed

Source PDF · page 13Printed manual reference: 304

C0242

Command / diagnostic

Multiple configuration of a parameter (->S-0-0423)

Source PDF · page 13Printed manual reference: 306

C0244

Command / diagnostic

Act. modulo value cycle greater than max. travel range

Source PDF · page 13Printed manual reference: 308

C0245

Command / diagnostic

Operation mode configuration (->S-0-0423) not allowed

Source PDF · page 13Printed manual reference: 308

C0251

Command / diagnostic

Error during synchronization to master communication

Source PDF · page 13Printed manual reference: 309

C0252

Command / diagnostic

Incorrect MLD initialization (write access->S-0-0423)

Source PDF · page 13Printed manual reference: 310

C0253

Command / diagnostic

Error in combination operation mode - encoder (->S-0-0423)

Source PDF · page 13Printed manual reference: 310

C0258

Command / diagnostic

Error in relation TNcyc (S-0-0001) to fine interpol

Source PDF · page 13Printed manual reference: 311

C0260

Command / diagnostic

Incremental enc. emulator resol. cannot be displayed

Source PDF · page 13Printed manual reference: 313

C0270

Command / diagnostic

Error when reading encoder data => motor encoder

Source PDF · page 14Printed manual reference: 315