Industrial motion control since 1988 · Search part numbers210-680-9570 · Se Habla Español
Menu
Controls · 04VRS

IndraMotion MLC 04VRS fault codes & diagnostics

IndraMotion MLC 04VRS diagnostic index: source-listed messages and printed manual references. Match this firmware to your equipment before using a code.

Check the source and revision

Document identification is not visible in the supplied excerpt.

28-page diagnostic index excerpt · 04VRS

These are the manufacturer’s index descriptions, not complete causes or repair instructions. “Source PDF page” opens the supplied index; “printed manual reference” identifies the destination in the full manual, which may not be included here.

Find a display message

Keep every letter, number and indicator. These entries describe the source document, not the condition of a particular machine.

Showing 401–480 of 1167 source entries

F0220513

Control diagnostic

MaxNumberOfMarkerFailure is not in valid range

Source PDF · page 10Printed manual reference: 112

F0220521

Control diagnostic

TOUCHPROBE_REF is not valid or wrong configuration

Source PDF · page 11Printed manual reference: 114

F0220522

Control diagnostic

AXIS_REF is not valid or wrong configuration of axis

Source PDF · page 11Printed manual reference: 114

F0220609

Control diagnostic

Wrong point type, point in world or joint coordinates

Source PDF · page 11Printed manual reference: 116

F0260001

Control diagnostic

MC_DigitalCamSwitch, Unable to acquire APS reference

Source PDF · page 11Printed manual reference: 116

F0260002

Control diagnostic

MC_DigitalCamSwitch, Unable to open cyclic channel

Source PDF · page 11Printed manual reference: 116

F0260003

Control diagnostic

MC_DigitalCamSwitch, Unable to allocate memory

Source PDF · page 11Printed manual reference: 116

F0260004

Control diagnostic

MC_DigitalCamSwitch, Unable to read parameter

Source PDF · page 11Printed manual reference: 116

F0260005

Control diagnostic

MC_DigitalCamSwitch, Invalid combination of units

Source PDF · page 11Printed manual reference: 116

F0260006

Control diagnostic

MC_DigitalCamSwitch, On-/Off compensation time longer 16sec

Source PDF · page 11Printed manual reference: 117

F0260007

Control diagnostic

MC_DigitalCamSwitch, Invalid state of state machine

Source PDF · page 11Printed manual reference: 117

F0260010

Control diagnostic

ML_PIDType01, Low limit is higher than High limit

Source PDF · page 11Printed manual reference: 117

F0260012

Control diagnostic

ML_PIDType01, Selected controller type not supported

Source PDF · page 11Printed manual reference: 117

F0260042

Control diagnostic

Function block may not be located in RETAIN data area

Source PDF · page 11Printed manual reference: 118

F0280030

Control diagnostic

C2C Error command S-0-0127, P3 transition check

Source PDF · page 11Printed manual reference: 121

F0280032

Control diagnostic

C2C Error command S-0-0128, P4 transition check

Source PDF · page 12Printed manual reference: 122

F0280047

Control diagnostic

C2C Producer cycle time less than SERCOS cycle time

Source PDF · page 12Printed manual reference: 123

F0280048

Control diagnostic

C2C Producer cycle time no multiple of SERCOS cycle time

Source PDF · page 12Printed manual reference: 123

F0280055

Control diagnostic

C2C Consumer data field length not corresponding

Source PDF · page 12Printed manual reference: 124