Industrial motion control since 1988 · Search part numbers210-680-9570 · Se Habla Español
Menu
Controls · 02VRS

IndraMotion MLC 02VRS fault codes & diagnostics

IndraMotion MLC 02VRS diagnostic index: source-listed messages and printed manual references. Match this firmware to your equipment before using a code.

Check the source and revision

DOK-IM*MLC-DIAGN***V02-WA01-EN-P

11-page diagnostic index excerpt · 02VRS

These are the manufacturer’s index descriptions, not complete causes or repair instructions. “Source PDF page” opens the supplied index; “printed manual reference” identifies the destination in the full manual, which may not be included here.

Find a display message

Keep every letter, number and indicator. These entries describe the source document, not the condition of a particular machine.

Showing 81–160 of 407 source entries

A00D07FD

Control diagnostic

Division (REAL) by zero - Divisor modified to 1.0!

Source PDF · page 3Printed manual reference: 4-31

A00D07FE

Control diagnostic

Lower range bounds (unsigned) violation - Value to MIN!

Source PDF · page 3Printed manual reference: 4-32

A00D07FF

Control diagnostic

Upper range bounds (unsigned) violation - Value to MAX!

Source PDF · page 3Printed manual reference: 4-32

A00D0800

Control diagnostic

Lower range bounds (signed) violation - Value to MIN!

Source PDF · page 3Printed manual reference: 4-33

A00D0801

Control diagnostic

Upper range bounds (signed) violation - Value to MAX!

Source PDF · page 3Printed manual reference: 4-33

A00D0802

Control diagnostic

Division (LREAL) by zero - Divisor modified to 1.0!

Source PDF · page 3Printed manual reference: 4-34

A00D0803

Control diagnostic

Invalid pointer access (address) - Pointer to a dummy!

Source PDF · page 3Printed manual reference: 4-34

A00D0804

Control diagnostic

Invalid pointer access (area) - Pointer to a dummy!

Source PDF · page 3Printed manual reference: 4-35

A00D0805

Control diagnostic

Invalid pointer access (W rite on input)- Pointer to a dumm y!

Source PDF · page 4Printed manual reference: 4-35

A00D0806

Control diagnostic

Invalid pointer access (alignment) - Pointer to a dumm y!

Source PDF · page 4Printed manual reference: 4-35

A00D1200

Control diagnostic

W riteParameter, inputs do not fit to attribute of parameter

Source PDF · page 4Printed manual reference: 4-36

A00D1201

Control diagnostic

W riteParameter, inputs do not fit to attribute of parameter

Source PDF · page 4Printed manual reference: 4-36

A00D1202

Control diagnostic

W riteParameter, inputs do not fit to attribute of parameter

Source PDF · page 4Printed manual reference: 4-37

A00D1203

Control diagnostic

W riteParameter, inputs do not fit to attribute of parameter

Source PDF · page 4Printed manual reference: 4-37

A00D1204

Control diagnostic

W riteParameter, parameter types are not supported

Source PDF · page 4Printed manual reference: 4-37

E00C0001

Control diagnostic

Parameter inconsistent, restorage via C-0-1001

Source PDF · page 4Printed manual reference: 4-43

E00D1001

Control diagnostic

W riteaccess to parameter S-0-0000 of UserCmdDataX

Source PDF · page 4Printed manual reference: 4-44

E00E0026

Control diagnostic

Version conflict in error logbook, logbook deleted!

Source PDF · page 4Printed manual reference: 4-44

E0112049

Control diagnostic

Positioning velocity greater than (A-0-0032/ 33)

Source PDF · page 4Printed manual reference: 4-48

E0112063

Control diagnostic

Commanded velocity greater than Limit (A-0-0032/ 33)

Source PDF · page 4Printed manual reference: 4-48

F00A0001

Control diagnostic

Parameter write-error during import, see C-0-0114

Source PDF · page 5Printed manual reference: 4-50

F00A0004

Control diagnostic

Import: length of line in import file exceeded maximum

Source PDF · page 5Printed manual reference: 4-51

F00A0005

Control diagnostic

Import/Export: unsupported Sercos parameter format

Source PDF · page 5Printed manual reference: 4-51