Industrial motion control since 1988 · Search part numbers210-680-9570 · Se Habla Español
Menu
Power supplies · Second generation

HVE / HVR second-generation supplies fault codes & diagnostics

Second-generation HVE and HVR supply displays, warnings and errors. Model-specific restrictions are included beside the relevant code.

Check the source and revision

DOK-POWER*-HVE+HVR**G2-AW07-EN-P

1-page display overview · Second generation

Find a display message

Keep every letter, number and indicator. These entries describe the source document, not the condition of a particular machine.

Showing 1–27 of 27 source entries

bb

Supply diagnostic

Ready for power on

Supply and drive status indicates readiness; this is an operating state, not an instruction to energize the machine.

Source PDF · page 1Printed manual reference: 11-4

Lb

Supply diagnostic

Power OK

The source describes the mains contactor as on and the DC bus voltage within its permitted range.

Source PDF · page 1Printed manual reference: 11-4

14

Supply diagnostic

External component warning

An additional component is reporting a warning. The source specifies power-off after 30 seconds.

Source PDF · page 1Printed manual reference: 11-4

15

Supply diagnostic

Control voltage temperature warning

HVR only: the control-voltage supply is overloaded and its temperature pre-warning contact has opened.

Source PDF · page 1Printed manual reference: 11-4

17

Supply diagnostic

Power off with bus shorting

Power is off and the DC bus dynamic brake is active.

Source PDF · page 1Printed manual reference: 11-4

18

Supply diagnostic

Heatsink overtemperature fault

Power is off because heatsink or power-section temperature is too high.

Source PDF · page 1Printed manual reference: 11-4

20

Supply diagnostic

Bleeder overload

Rotary-drive energy (HVE/HVR), or regenerated power (HVE), is too high.

Source PDF · page 1Printed manual reference: 11-4

23

Supply diagnostic

Drive fault

The supply has switched power off in response to a drive error.

Source PDF · page 1Printed manual reference: 11-4

24

Supply diagnostic

External component error

An additional component, such as the bleeder loading device, is reporting a fault.

Source PDF · page 1Printed manual reference: 11-4

25

Supply diagnostic

Regenerative power overload

Continuous regenerated drive power is excessive.

Source PDF · page 1Printed manual reference: 11-4

26

Supply diagnostic

Bus power overload

Continuous drive feed-in power is excessive.

Source PDF · page 1Printed manual reference: 11-4

50

Supply diagnostic

Heatsink temperature warning

The temperature pre-warning contact is open; the source specifies power-off after a further 5 °C rise.

Source PDF · page 1Printed manual reference: 11-4

52

Supply diagnostic

Bleeder overload warning

Excessive regenerated power has reached 80% of the allowable bleeder on-time.

Source PDF · page 1Printed manual reference: 11-4

60

Supply diagnostic

Overcurrent

HVR only: the source lists a possible short circuit in the supply, drive, motor or cable.

Source PDF · page 1Printed manual reference: 11-4

69

Supply diagnostic

+24 V / ±15 V / +5 V fault

The control voltages are faulty.

Source PDF · page 1Printed manual reference: 11-4

80

Supply diagnostic

Short to ground

The source identifies a ground fault in the supply, drive, motor or cable.

Source PDF · page 1Printed manual reference: 11-4

81

Supply diagnostic

Power failure

HVR only: one or more mains phases are missing.

Source PDF · page 1Printed manual reference: 11-4

82

Supply diagnostic

Phase-loss fault

HVE only: one or more mains phases are missing, or mains voltage is too low.

Source PDF · page 1Printed manual reference: 11-4

83

Supply diagnostic

Line voltage fault

Mains voltage is outside the permitted tolerance.

Source PDF · page 1Printed manual reference: 11-4

84

Supply diagnostic

Miswiring

HVR only: the source describes a phase mismatch between power and control-voltage connections; the line contactor does not pick up.

Source PDF · page 1Printed manual reference: 11-4

85

Supply diagnostic

Line frequency fault

HVR only: mains frequency is outside the permitted tolerance.

Source PDF · page 1Printed manual reference: 11-4

87

Supply diagnostic

Control voltage supply failure

HVE only: control-voltage supply is outside the permitted tolerance.

Source PDF · page 1Printed manual reference: 11-4

94

Supply diagnostic

Checksum error

HVR only: the source identifies a hardware or software error in the unit.

Source PDF · page 1Printed manual reference: 11-4

. .

Supply diagnostic

Device failure

The source identifies a hardware or software error in the unit.

Source PDF · page 1Printed manual reference: 11-4

_ _

Supply diagnostic

+5 V failure

HVE only: failure of the +5 V control voltage.

Source PDF · page 1Printed manual reference: 11-4

E1–E9

Supply diagnostic

Device failure

HVE only: the source identifies a hardware or software error in the unit.

Source PDF · page 1Printed manual reference: 11-4