Industrial motion control since 1988 · Search part numbers210-680-9570 · Se Habla Español
Menu
DIAX drives · Match the installed firmware

DIAX02 — DDS / DKS / DDC fault codes & diagnostics

DDS, DKS and DDC diagnostics with separate H1 and H2 indicators. Includes status displays and faults from the supplied DIAX02 guide.

Check the source and revision

DOK-DIAX02-DDS+DKS+DDC-WAR1-EN-E1,44

23-page guide excerpt · Match the installed firmware

All displayed diagnostic headings in supplied sections 2.1 (H1) and 2.2 (H2); supplied extract does not include referenced section 2.3 Command Errors.

Find a display message

Keep every letter, number and indicator. These entries describe the source document, not the condition of a particular machine.

Showing 81–96 of 96 source entries

_

H2 · fault

EPROM checksum error

The SERCOS interface EPROM is faulty. The graphic shows only the bottom horizontal segment. '_' is a searchable transcription, not a normal numeral.

Source PDF · page 21Printed manual reference: 27

Segment pattern

H2 · fault

Invalid communications phase

The NC control attempted to switch into a currently invalid communications phase. All four vertical segments lit; horizontal segments unlit. The supplied graphic has no ordinary alphanumeric equivalent. code is null intentionally; use the display description or source page instead of inventing a character.

Source PDF · page 21Printed manual reference: 27

Segment pattern

H2 · fault

Error during phase progression

The NC control attempted an invalid communications phase progression. Upper-right and both left vertical segments lit; other segments unlit. The supplied graphic has no ordinary alphanumeric equivalent. code is null intentionally; use the display description or source page instead of inventing a character.

Source PDF · page 21Printed manual reference: 27

Segment pattern

H2 · fault

Error during phase regression

The NC control attempted an invalid communications phase regression. Lower-right and both left vertical segments lit; other segments unlit. The supplied graphic has no ordinary alphanumeric equivalent. code is null intentionally; use the display description or source page instead of inventing a character.

Source PDF · page 21Printed manual reference: 27

0

H2 · temporary status

No progression to Phase 1

The NC control has not yet triggered progression from Phase 0 to Phase 1.

Source PDF · page 21Printed manual reference: 27

1

H2 · temporary status

NC control unit has not yet triggered progression to Phase 2

The NC control has not yet triggered progression from Phase 1 to Phase 2.

Source PDF · page 22Printed manual reference: 28

2

H2 · fault

Invalid parameters for Phase 3

Invalid parameters prevent progression to Communications Phase 3.

Source PDF · page 22Printed manual reference: 28

3

H2 · fault

Invalid parameters for Phase 4

Invalid parameters prevent progression to Communications Phase 4. The original remedy paragraph repeats the Phase 2 list S-0-0021 despite this Phase 4 heading. No correction or parameter-changing remedy is supplied here.

Source PDF · page 22Printed manual reference: 28

4

H2 · status

Cyclical operation

The SERCOS ring is in cyclic operation and communication is established.

Source PDF · page 22Printed manual reference: 28

6

H2 · temporary status

MST not yet received

No master synchronization telegram indicating Communications Phase 0 has been received.

Source PDF · page 23Printed manual reference: 29

A

H2 · fault

Address 0 set

The SERCOS interface address is set to the invalid value 0.

Source PDF · page 23Printed manual reference: 29

b

H2 · fault

Double MDT error

A double master-data-telegram error is detected from Communications Phase 3 onward.

Source PDF · page 23Printed manual reference: 29

o

H2 · fault

Double MST error

A double master-synchronization-telegram error is detected from Communications Phase 3 onward.

Source PDF · page 23Printed manual reference: 29