_
H2 · faultEPROM checksum error
The SERCOS interface EPROM is faulty. The graphic shows only the bottom horizontal segment. '_' is a searchable transcription, not a normal numeral.
Source PDF · page 21 ↗Printed manual reference: 27DDS, DKS and DDC diagnostics with separate H1 and H2 indicators. Includes status displays and faults from the supplied DIAX02 guide.
DOK-DIAX02-DDS+DKS+DDC-WAR1-EN-E1,44
23-page guide excerpt · Match the installed firmware
All displayed diagnostic headings in supplied sections 2.1 (H1) and 2.2 (H2); supplied extract does not include referenced section 2.3 Command Errors.
Keep every letter, number and indicator. These entries describe the source document, not the condition of a particular machine.
Showing 81–96 of 96 source entries
EPROM checksum error
The SERCOS interface EPROM is faulty. The graphic shows only the bottom horizontal segment. '_' is a searchable transcription, not a normal numeral.
Source PDF · page 21 ↗Printed manual reference: 27Invalid communications phase
The NC control attempted to switch into a currently invalid communications phase. All four vertical segments lit; horizontal segments unlit. The supplied graphic has no ordinary alphanumeric equivalent. code is null intentionally; use the display description or source page instead of inventing a character.
Source PDF · page 21 ↗Printed manual reference: 27Error during phase progression
The NC control attempted an invalid communications phase progression. Upper-right and both left vertical segments lit; other segments unlit. The supplied graphic has no ordinary alphanumeric equivalent. code is null intentionally; use the display description or source page instead of inventing a character.
Source PDF · page 21 ↗Printed manual reference: 27Error during phase regression
The NC control attempted an invalid communications phase regression. Lower-right and both left vertical segments lit; other segments unlit. The supplied graphic has no ordinary alphanumeric equivalent. code is null intentionally; use the display description or source page instead of inventing a character.
Source PDF · page 21 ↗Printed manual reference: 27No progression to Phase 1
The NC control has not yet triggered progression from Phase 0 to Phase 1.
Source PDF · page 21 ↗Printed manual reference: 27NC control unit has not yet triggered progression to Phase 2
The NC control has not yet triggered progression from Phase 1 to Phase 2.
Source PDF · page 22 ↗Printed manual reference: 28Invalid parameters for Phase 3
Invalid parameters prevent progression to Communications Phase 3.
Source PDF · page 22 ↗Printed manual reference: 28Invalid parameters for Phase 4
Invalid parameters prevent progression to Communications Phase 4. The original remedy paragraph repeats the Phase 2 list S-0-0021 despite this Phase 4 heading. No correction or parameter-changing remedy is supplied here.
Source PDF · page 22 ↗Printed manual reference: 28Cyclical operation
The SERCOS ring is in cyclic operation and communication is established.
Source PDF · page 22 ↗Printed manual reference: 28Hardware error
A general hardware error is indicated.
Source PDF · page 22 ↗Printed manual reference: 28MST not yet received
No master synchronization telegram indicating Communications Phase 0 has been received.
Source PDF · page 23 ↗Printed manual reference: 29Test mode
The SERCOS interface has switched to test mode.
Source PDF · page 23 ↗Printed manual reference: 29Test mode
The SERCOS interface has switched to test mode.
Source PDF · page 23 ↗Printed manual reference: 29Address 0 set
The SERCOS interface address is set to the invalid value 0.
Source PDF · page 23 ↗Printed manual reference: 29Double MDT error
A double master-data-telegram error is detected from Communications Phase 3 onward.
Source PDF · page 23 ↗Printed manual reference: 29Double MST error
A double master-synchronization-telegram error is detected from Communications Phase 3 onward.
Source PDF · page 23 ↗Printed manual reference: 29